Are brick chimneys and unreinforced masonry an earthquake risk?
What California, Washington and Utah agency guides say about brick chimneys and unreinforced masonry walls in earthquakes, and who should evaluate them.
On this page: 8 sections
- 1Can an unreinforced brick chimney fall in an earthquake?
- 2Do unreinforced masonry walls and foundations fail in earthquakes too?
- 3How can you tell from outside whether walls are unreinforced masonry?
- 4What do the agency guides look at in a brick chimney's mortar and attachment?
- 5Who should evaluate a masonry chimney or wall?
- 6How are masonry chimneys strengthened or rebuilt?
- 7Should people stay clear of a chimney during shaking?
- 8What happens after an earthquake damages a masonry chimney or house?
Yes: California's earthquake guide for homeowners states that an unreinforced brick or stone chimney could collapse during an earthquake and fall on the ground beside the home or through the roof. In California homes with unreinforced masonry walls, the walls may be too brittle to resist earthquake shaking and could collapse.1
Can an unreinforced brick chimney fall in an earthquake?
In Washington, unreinforced masonry chimneys may crumble or topple during an earthquake, posing a hazard to roofs, people and nearby vehicles. Washington's guide adds that unreinforced masonry chimneys tend to break at the roofline or peel away from the house, and that the likelihood of breakage increases with chimney height.2
San Bernardino County assessment teams observed over 50 brick masonry chimneys damaged in the July 4 and 5, 2019 Trona earthquakes. In San Bernardino County's bulletin, older unreinforced masonry chimneys with degraded mortar are most vulnerable, but even masonry chimneys constructed according to modern standards are susceptible to significant damage.3
California's guide lists the unreinforced masonry chimney among other structural risks that are left out of the state's Residential Earthquake Risk Disclosure Statement because, typically, it is not cost effective to complete a retrofit, and the guide adds that these risks should be considered by a homeowner or a potential home buyer.1
Do unreinforced masonry walls and foundations fail in earthquakes too?
In California's guide, unreinforced masonry walls are walls built of brick, hollow clay tiles, stone, concrete blocks or adobe, and an unreinforced masonry foundation is a brick, stone or concrete block foundation that lacks steel reinforcing. A California home on an unreinforced masonry foundation could slide off its foundation during an earthquake, because the foundation may not be able to resist earthquake shaking.1 In Washington, foundations built from bricks, concrete blocks or mortared stone often fail during earthquakes.2
A parapet is a low wall along the edge of a roof or balcony. In Washington's guide, older unreinforced masonry parapets can fall apart during an earthquake, damaging the house and possibly causing injury.2
Most unreinforced masonry buildings in California possess features that can threaten lives during earthquakes, including unbraced parapets and walls and roofs that are not well attached to each other. When earthquakes occur, inadequate connections can allow masonry to fall and floors and roofs to collapse, and the California commission's report states that these risks to life can be significantly reduced with seismic retrofits. California enacted a law in 1986 that required local governments in Seismic Zone 4 to inventory unreinforced masonry buildings, and the commission's April 2000 report counted about 96 percent of the 25,500 unreinforced masonry buildings in loss reduction programs.4
How can you tell from outside whether walls are unreinforced masonry?
California's check for unreinforced masonry walls starts with a walk around the perimeter of the home to look for evidence of unreinforced brick, clay tile, stone, adobe or concrete-block wall construction, looking closely at wall surfaces at windows and doors. Where the exterior walls are covered with plaster, California's guide has the walls examined from inside the home, for example beneath light switch plates. Steel plates and anchor bolts are common retrofits on California masonry walls, and the guide lists them as indicators of retrofit.1
Utah's checklist for historic houses asks whether bricks are cracked, loose, spalled or missing, and whether header bricks are absent on walls built of multiple layers of brick. A header brick is a brick laid with its narrow end facing out. A Utah house that draws a yes to any question on the checklist may be at greater risk from an earthquake.5
What do the agency guides look at in a brick chimney's mortar and attachment?
California's guide describes a chimney check in three parts: the mortar is checked with a screwdriver, the attic area above the fireplace is used to verify that the chimney is securely attached to the home with metal straps or ties, and a homeowner who is unable to verify the strength of the chimney consults a licensed engineer or architect or a general contractor. In California's guide, chimney mortar that crumbles may be too weak to withstand earthquake shaking.1 Washington's guide describes a similar check, in which the grout between a chimney's brick or stones is picked at with a knife and should not crumble.2 Utah's checklist asks whether masonry chimneys, parapets or gables are unbraced, unreinforced or not secured to the roof or ceiling structure, and whether the mortar on the chimney is deteriorated.5
Who should evaluate a masonry chimney or wall?
A California homeowner who is unable to verify the strength of a chimney should consult a licensed engineer or architect or a general contractor. For unreinforced masonry walls, California's guide points a homeowner who does not know what to look for to a licensed engineer or architect.1
Washington's guide recommends having a licensed engineer check whether a masonry foundation has been reinforced, and contacting a professional engineer to evaluate a parapet.2 In Utah, substantial retrofits such as adding new foundations or shear walls may require the professional assistance of a licensed engineer, architect or contractor.5 San Bernardino County's bulletin adds that an engineered approach may be appropriate or necessary in some dwellings.3
How are masonry chimneys strengthened or rebuilt?
Washington's guide lists three reinforcement measures for a masonry chimney: replacing the chimney above the roofline with lighter metal flues that may be veneered to match the lower brickwork, adding plywood above the ceiling joists in the attic or directly beneath the roof shingles near the chimney to prevent any collapsing brickwork from damaging the interior of the home, and reinforcing the masonry with additional anchorage at each floor, roof and ceiling to meet design standards.2
In San Bernardino County, repair of older, unreinforced masonry chimneys to meet modern seismic performance standards is generally considered to be infeasible, and such chimneys may remain vulnerable to collapse in future earthquakes. San Bernardino County's recommended practice for reducing future damage involves partial or complete removal of the masonry and reconstruction with metal flues or fireplace inserts and light frame construction. The county's alternatives run from capping of the chimney at the roof level to full reconstruction of the firebox and chimney.3
Repointing is restoring the outside surface of deteriorated mortar joints. San Bernardino County's bulletin treats repointing or patching of isolated masonry cracks as not sufficient: the work will do little to reduce the potential for damage in future earthquakes.3 Utah's guide reports that repointed chimneys performed better in the 1992 St. George earthquake than loose, deteriorated chimneys.5 Masonry chimneys in San Bernardino County should not be retrofitted using steel braces that extend down to the roof surface, because such bracing is thought to have promoted chimney failure in past earthquakes.3
Should people stay clear of a chimney during shaking?
California's guide gives two precautions for a home with an unreinforced masonry chimney: avoid parking cars or locating patios or children's play areas within the falling radius of the chimney, and remind home occupants to stay away from chimneys and fireplaces during earthquakes. California's earthquake safety tips tell people indoors to stay clear of windows, fireplaces and heavy furniture or appliances, and people outdoors to move away from buildings, power lines, chimneys and anything else that might fall.1
Washington's advice for anyone outside during an earthquake is to move out into the open and avoid anything that might fall, including buildings, chimneys, trees, light posts and power lines.2 San Bernardino County's bulletin recommends minimizing time spent next to a masonry chimney, both inside and outside the dwelling, and states that sleeping adjacent to a masonry chimney should be avoided.3
What happens after an earthquake damages a masonry chimney or house?
In Utah, a house that an inspector determines is unsafe should not be occupied. Red tagging in Utah typically means the building should not be occupied, rather than demolished, and Utah's guide recommends a second opinion from a professional engineer or architect experienced with historic buildings.5
The City of San Luis Obispo's bulletin sets a standard for a masonry to metal chimney transition and requires that the firebox, chimney and other undamaged areas be carefully visually inspected for cracks or voids before any construction. Cracks or voids in a San Luis Obispo chimney matter because they may permit the access of flames or smoke to the surrounding wood framing. Under the San Luis Obispo standard, the height of the chimney above the roof is limited to ten feet.6
The California Seismic Safety Commission, the Washington Geological Survey, the Utah Division of State History, San Bernardino County and the City of San Luis Obispo, checked November 2026.
Sources (6)
- California Seismic Safety Commission: Homeowner's Guide to Earthquake Safety, read November 25, 2026 ↑
- Washington Geological Survey: Protect Your Home and Property, read November 25, 2026 ↑
- San Bernardino County Land Use Services: Repair of Earthquake-Damaged Masonry Fireplace Chimneys, read November 25, 2026 ↑
- California Seismic Safety Commission: Status of California's Unreinforced Masonry Building Law, read November 25, 2026 ↑
- Utah Division of State History: Bracing for the Big One, read November 25, 2026 ↑
- City of San Luis Obispo: Information Bulletin 1-2004, read November 25, 2026 ↑